What the method actually is
Every other detection method listens to a leak, looks at the heat it makes, or measures the damp it leaves behind. Tracer gas does something different: it replaces the water with a gas that can get out of the building, and then finds the gas.
The gas is a mixture of 5% hydrogen in 95% nitrogen. Sewerin, who make the detectors most UK leak engineers carry, describe it as non-toxic and non-corrosive, and safe to use on drinking water pipework. It is sold in the UK as a standard cylinder gas, the same blend the refrigeration trade has used for years. Hydrogen is the smallest molecule there is, so it passes through openings that water only weeps through, and it is buoyant, so once it is out of the pipe it goes up rather than sideways.
The part that matters for your floor: hydrogen will come up through asphalt, concrete, screed and soil. That is why the method is described as non-invasive. Nothing is lifted to find the leak. Something is lifted afterwards, at one point, to repair it.
How a tracer gas visit runs
- Isolate and prove the loss. Before any gas comes off the van, the suspect circuit is isolated and pressure tested. This confirms there is a real loss and separates a leaking pipe from a failed expansion vessel, a passing valve or a shower tray that only leaks when someone stands in it.
- Drain the circuit. This is the step people are not told about, and it is the method's biggest constraint. Water left in the pipe blocks the gas and keeps escaping at the leak, so the detector follows the water rather than the gas. The pipe has to be empty.
- Charge the pipe with the mixture. The gas goes in through a regulator at a low, controlled pressure, usually via a drain point, a radiator tail or a manifold port. It fills the run and finds the same hole the water was finding.
- Sweep the surface. The engineer walks the floor with a hydrogen probe, in a grid, moving slowly. Detectors of this class read from single parts per million upwards, so the first indication is often well before the strongest one.
- Find the peak, then confirm it. A single reading is not a result. The engineer works out from the first hit in both directions to establish where the signal is strongest and where it falls away, then re-tests after airing the room to make sure the peak repeats.
- Mark and open once. The floor is cut at the marked point, the leak is exposed, and the pipe is repaired. On a screed floor that is typically a single access hole rather than a lifted floor.
What tracer gas finds that acoustic and thermal cannot
Leaks under screed and concrete
A pipe buried in 60mm of screed under tile is acoustically dead and thermally muted. Acoustic kit needs the leak noise to travel to a surface the engineer can put a microphone on, and screed absorbs it. Thermal imaging needs the leak to change the surface temperature enough to see, which it often does not on a slow weep or a cold-water pipe. Gas does not care about either. It leaves the pipe, works its way up through the screed and arrives at the tile grout.
Leaks on plastic pipe
Plastic pipework, particularly MDPE on a supply run and barrier pipe in a heating screed, is the acoustic method's worst case. Leak noise in plastic pipes is heavily attenuated with distance and what survives is low frequency and narrow band, which is exactly the part of the spectrum that a building's own noise floor sits in. Most of London's post-1990 supply pipes and nearly all underfloor heating circuits are plastic. Tracer gas works the same on plastic as on copper, because the gas leaves through the hole either way.
Systems that make no noise at all
Acoustic detection needs pressure. A leak on an unpressurised system, a gravity circuit, a drain, or a heating system that has already emptied itself makes nothing to listen to. Sewerin market their tracer gas detector specifically for leaks in what they call noiseless and unpressurised areas, which is an honest description of the gap it fills. If your boiler gauge has dropped to zero and stays there, there is nothing for a microphone to hear, and gas is the method that still works.