London-wide leak specialists
ResidentialCommercial
Get in touch
Book an engineer

How long a hot water cylinder lasts, and when to replace it

Most cylinders in London give somewhere between ten and twenty-five years, and the range is that wide because hardness, running temperature, material and whether the expansion vessel was ever checked matter far more than age does. Anything wet at a seam or weld is end-of-life; anything wet at a fitting usually is not.

Leak Fix LondonLast updated

A Leak Fix London engineer working on pipework in a London home

Age is the worst predictor on the list

People ask how many years they should get. It is a fair question with an unsatisfying answer: the honest range is wide, roughly ten to twenty-five years for a domestic cylinder, and we have seen both ends of it in the same street. Two identical cylinders fitted the same week can be eight years apart at the end, and the difference is almost never the badge on the front.

These are ranges, not specifications. No one can give you a real figure for your cylinder without looking at it. What we can do is tell you what the variables are, because once you know them you can usually place your own cylinder in the range yourself.

The four things that actually decide it

1. How hard your water is

Every drop of water in the Thames Water region is hard — the company says so itself, because the supply passes through chalk and limestone before it reaches you. Hard water and stored hot water are a bad combination. Above roughly 60°C, calcium comes out of solution and forms scale, and scale goes straight to the hottest surface it can find.

In a direct cylinder that is the immersion heater element, which scales, overheats and fails. In an indirect cylinder it is the coil, which loses efficiency long before it fails, so the first sign is that the hot water runs out sooner than it used to rather than anything dramatic. Scale also settles in the base of the vessel, where it holds a damp layer against the metal and gives corrosion somewhere to start.

A London cylinder is doing harder work than the same cylinder in a soft-water area. That alone shifts the likely life down the range.

2. What temperature it has been run at for years

There is a genuine conflict here and it is worth understanding rather than guessing. Stored water needs to be hot enough to control legionella — the control guidance that landlords and workplaces work to sets storage at 60°C — but every degree above that accelerates both scaling and thermal stress on the vessel.

A cylinder that has spent fifteen years running at a scalding setting because someone turned the thermostat up once and never turned it back has aged faster than its years. If you cannot hold your hand under the hot tap at all, the storage temperature is probably higher than it needs to be. That is a thermostat and blending question for whoever services the system, not a reason to replace anything — but it tells you something about the cylinder's history.

3. What it is made of

TypeHow it tends to failWhat that means for you
Copper, vented (the old tank-fed kind)Pinholes, usually low down or near a boss; sometimes a split seamFails slowly and visibly. Often weeps for weeks before anything else happens.
Stainless steel, unventedWeld or seam failure, often accelerated by chloride pittingCan fail with very little warning, and at full mains pressure.
Glass-lined steel with a sacrificial anodeAnode depletes, then the steel starts corrodingLife depends almost entirely on whether the anode was ever replaced.

The pattern matters more than the material. A copper cylinder tends to warn you. An unvented stainless one is holding mains pressure, so when it goes it can put out a great deal of water very quickly.

4. Whether the expansion arrangement was maintained

This is the one that gets ignored, and on an unvented cylinder it is arguably the most important of the four.

Water expands when it heats. A vented system pushes that expansion back up to the loft tank. An unvented cylinder has nowhere to put it except an expansion vessel, or an internal air bubble on the bubble-top designs. When the vessel loses its air charge — and they all do eventually — the expansion has nowhere to go, so every heating cycle drives the pressure up until the expansion relief valve opens and dumps to the tundish.

The symptom is water trickling from the outside discharge pipe, usually after the cylinder has reheated. People live with that for years and treat it as normal. It is not. The cylinder is now taking a full pressure cycle every heating period, the relief valve is being worked constantly and will eventually stick, and the vessel or the internal bubble needs recharging. An unvented cylinder is supposed to be checked annually for exactly this reason. One that has never been touched is the single most common reason a cylinder fails early.

Signs it is near the end, and signs it is just broken

These are two different lists, and the distinction is usually worth a lot of money.

Usually fixable, not end-of-life

  • Water at a fitting, boss, immersion flange or thermostat pocket — that is a seal or a joint.
  • Drips from the tundish or the outside discharge pipe — expansion vessel or a relief valve, not the vessel itself.
  • Hot water running out faster than it used to — usually scale on the coil or a failed thermostat.
  • Rumbling or kettling noises on reheat — scale in the base.
  • Wet insulation with a dry vessel underneath — trace it upwards, it is often a pipe above.

End-of-life

  • Any weeping at a seam or weld. This one is not a judgement call.
  • Rust staining running down the outside of the vessel from under the foam.
  • Green verdigris trails on copper that come back after you dry them.
  • More than one pinhole already repaired.
  • Cloudy or rusty hot water when the cold runs clear.

Why a weeping seam is different

A seam is where the vessel was joined. It is under stress from every heating and cooling cycle, and there is no way to repair it from the outside that a pressurised vessel will respect for long. Once water is coming through a seam, the vessel has lost its integrity and pressure cycling will keep opening it further.

These do not reverse. A seam that is weeping today will be weeping faster in six months, and the failure mode at the end is not another drip — it is the seam letting go, which on an unvented cylinder means the contents of the vessel and then the mains feeding it. That tends to happen on a reheat cycle, which is often overnight or in the middle of a working day, which is to say while nobody is home. A cylinder that fails in an airing cupboard on the first floor goes through the ceiling below it, and by the time anyone notices, you are dealing with a ceiling, a floor and whatever was under both.

We are not trying to sell you a cylinder — we do not fit them. We are telling you this because we get called to the aftermath, and the aftermath costs several times what the planned swap would have.

The repair-or-replace arithmetic, honestly

Work through it in this order:

  1. Is the leak on the vessel, or on something bolted to it? If it is on something bolted to it, fix that and stop. This is by far the most common answer and it is cheap.
  2. If it is the vessel, how old is it? Under about ten years in a hard-water area, it is worth asking why it failed early — a failed expansion arrangement that nobody fixed will simply do it again to the replacement.
  3. What else is tired? If the immersion has failed, the thermostat is unreliable and the expansion vessel is flat, you are spending repeatedly on a unit that is telling you something.
  4. What is underneath it? A cylinder in a ground-floor cupboard on a concrete slab is a different risk from one directly above a kitchen. The same failure carries a very different bill.
  5. Is anyone in the house during the day? An empty house shifts the answer towards replacing sooner, because nothing will be noticed for hours.

Where it is genuinely borderline, the question is not what the cylinder costs. It is what the failure costs, multiplied by how likely it is, against the cost of choosing the date yourself.

What we do here, and what we do not

We are a leak firm. We do not sell or fit cylinders, and we have no reason to push you towards a new one.

What we get called for is the case where something in the airing cupboard is wet and nobody can say what. That is worth a visit, because a wet cupboard floor is very often not the cylinder at all — it is a pipe above it, a discharge pipe routed badly, or condensation on a cold feed. We isolate, test and find out which, and we do it before anyone spends money on a vessel that was never the problem. Our rate is £150 an hour, agreed before we attend, and if we do not find the leak you do not pay for the looking.

If it is the cylinder and it is finished, we will say so plainly and you can get it swapped by whoever you like. If it is a pipe, we repair it — see water leak repair. And if a cylinder has already let go and taken a ceiling with it, we also do the making-good, and the written report from the visit is prepared to support a trace-and-access claim. What the insurer then covers is their decision, not ours.

Frequently asked

How long should a hot water cylinder last?
Roughly ten to twenty-five years, and that is a range rather than a figure. Hard water, a high storage temperature and an expansion vessel that has never been checked push a cylinder towards the bottom of it; soft water, a sensible thermostat setting and annual servicing push it towards the top.
My cylinder is weeping slightly at the seam. Can it be repaired?
No, not in any way that lasts. A seam is under stress from every heating cycle, and once water is coming through it, the vessel has lost its integrity. It will get worse, not better, and it should be replaced before it fails properly.
Water drips from the pipe outside after the hot water heats up. Is the cylinder failing?
Usually not. That is the expansion relief discharging, and it almost always means the expansion vessel has lost its air charge or the relief valve is passing. It is a service item rather than a new cylinder, but leaving it alone shortens the cylinder’s life, so it is worth sorting.
Do you replace hot water cylinders?
No. We find and repair leaks and reinstate the damage they cause. If we attend a wet airing cupboard we will tell you plainly whether the cylinder is the source and whether it is finished, then you can have it replaced by whoever you choose.
Does hard water in London really shorten a cylinder’s life?
It shortens it in practice, yes. Thames Water states that all the water in its region is hard, and stored hot water above about 60°C deposits scale on the hottest surfaces — the immersion element or the coil — and in the base of the vessel. It does not destroy a cylinder on its own, but it makes everything else happen sooner.

Sources