Which one you have, settled in ten seconds
Go into the loft. If there is a plastic or galvanised tank up there with a float valve in it, you have a vented system. The hot cylinder in the airing cupboard is fed by gravity from that tank, and the pressure at your taps comes from how far the tank sits above them — roughly 0.1 bar for every metre of height.
If the loft is empty and the cylinder in the cupboard is a fat white or copper drum with a bundle of valves on the cold feed and a small funnel-shaped fitting piped away from it, you have an unvented system. It is fed straight off the mains, sealed, and holds stored water at mains pressure. Megaflo is the best-known name for this type; it is a Heatrae Sadia product, and the same principles apply to every unvented cylinder whoever made it.
That one structural difference — open to the air at the top, or sealed under pressure — decides everything about how each of them fails.
How a vented system fails
The float valve that never quite shuts
The commonest vented failure is not the cylinder at all. It is the float valve in the loft tank wearing out, so the tank keeps filling past its working level. The tank is designed for exactly this: a warning pipe (the overflow) takes the excess out through the eaves and drips onto your path, which is the whole point of putting it where you can see it.
Two things go wrong with that design. The overflow can be blocked with silt, or it can have been badly run and discharge into the loft insulation instead of outside. And people ignore the drip. A pipe that drips outside for a fortnight is a nuisance; the same valve failing again in January when the overflow is frozen puts the whole flow into the loft. We wrote about the outside drip separately, in is a leaking overflow pipe dangerous.
The tank and the cylinder
Old galvanised tanks corrode at the waterline. Plastic tanks go brittle where the sun hits them through a roof light and split along a fold. A vented copper cylinder usually fails at a soldered boss or a seam, and because there is almost no pressure behind it, it weeps rather than sprays.
This is why vented failures are so late to show. A weep of a few litres a day goes into the loft floor, through the insulation, and spreads sideways across the ceiling plasterboard before it comes through anywhere. By the time you see a brown ring, the joists above it have usually been wet for weeks. The ceiling under a loft tank is the single most common place we are called to on a vented system — the symptom, not the cause, which is what a water stain on a ceiling almost always is.
How an unvented system fails
The tundish is doing its job, loudly
An unvented cylinder cannot vent expansion into a loft tank, because there isn't one. Heated water expands, and that expansion has to go somewhere. It goes into an expansion vessel, or into a deliberate air bubble held at the top of the cylinder. If that space disappears, pressure rises on every heating cycle until a relief valve lifts and dumps water.
The dumped water goes through the tundish — the small open funnel in the pipework, which under the Building Regulations has to sit close to the safety valve and somewhere you can actually see it — then down a discharge pipe and out to a safe place outside. A tundish with water running through it means a valve has lifted. A discharge pipe dripping outside, warm, whenever the hot water heats, means the same thing.
That is not a leak in the usual sense. Nothing has burst. The system is protecting itself, and the fault is almost always a lost expansion vessel charge or a tired relief valve. The same physics behind a heating system's vessel is covered in expansion vessel failure or a leak. This one is a G3-registered cylinder engineer's job, not a leak detection visit, and we will tell you so on the phone rather than attend.
When it is a real unvented leak
When an unvented cylinder or its pipework does fail properly, it fails at mains pressure and it fails fast. A pinhole on a compression joint in the cupboard sprays rather than weeps. Because the stored water is replaced by the mains as fast as it leaves, there is no tank volume to run out — it keeps going until someone closes the stopcock. Unvented cylinders also sit in cupboards on the ground or first floor far more often than in lofts, so the water lands on a floor you walk on and is found in hours, not weeks.