Stop it in this order
- If water is running onto or through anything electrical, deal with that first — but only if you can reach the consumer unit without standing in water and without touching anything wet. If you cannot, leave it, keep everyone out of that area, and use a torch rather than a light switch. The detail is in what to do if a pipe bursts.
- Close the internal stopcock. Clockwise, gently, until it stops. Usually under the kitchen sink; otherwise a downstairs cloakroom, utility, cellar, garage or under the stairs. In a flat it is often inside an airing cupboard or a service riser on the landing. The flow can take a minute or two to die away.
- Open every cold tap and flush every toilet. This is the step most people skip and it matters more than it sounds. The pipework is still full when you close the stopcock. Opening the taps sends what is left in it down the drain instead of out through the failure.
- Turn the boiler off at the programmer, and at its fused spur if the spur is dry.
- Deal with what stores water separately — the heating circuit, a hot water cylinder, a loft cistern. See the next section, because this is where an escape of water carries on after the mains are off.
- Photograph it wet, before you clean anything. Wide shots of the room, close shots of the source, a short video of water actually coming in. Insurers work from evidence, and the evidence dries.
If the stopcock will not turn, do not put a bar on it. A snapped spindle turns a leak you can stop into one you cannot. WaterSafe covers locating and using a stop tap, and what to do when the internal one is broken.
What the stopcock does not switch off
Closing the stopcock stops water entering the building. It does not empty what is already stored inside it, and on a lot of London properties that is a substantial volume sitting above the leak with gravity behind it.
| What it is | Does the stopcock stop it? | What actually stops it |
|---|---|---|
| Cold mains and any combi boiler | Yes, once the taps have run through | Stopcock, then open the taps |
| Sealed heating circuit and radiators | No. It holds its own water and the pump can still move it | Heating off, then drain the circuit, or close both valves on the offending radiator |
| Hot water cylinder | No. It stays full | Drain it through the lowest hot tap, or its drain cock |
| Loft cold water cistern, on older systems | It will not refill, but it will empty itself through the leak | Close the gate valve on its outlet, or drain it through the bath cold tap |
| Expansion or feed cistern for a vented heating system | No | Close its service valve, or tie the float arm up |
This is the whole reason a leak sometimes carries on for an hour after someone was sure they had turned the water off. They had. The building was still full.
The heating circuit
A sealed system is a closed loop. Once filled, it is independent of the mains, so a pinhole on a heating pipe keeps running with the stopcock shut. Switch the heating off so the pump stops pushing, then either drain the circuit properly at a drain-off cock on the lowest point, or, if you have identified a single radiator or towel rail as the source, close the wheel valve one end and the lockshield the other and you have isolated that one appliance without draining the house. Our step-by-step is in how to drain down your system.
A word of caution on draining down in winter: an empty system is a cold house. If it is freezing outside and the property will be left, that trade-off is worth thinking about, because frozen pipes are the next problem.
The cylinder
A hot water cylinder holds a couple of hundred litres in most houses. Unvented cylinders are fed from the mains, so the stopcock stops the refill, but the stored water is still under pressure and will keep going out of a failed joint until it equalises. Vented cylinders are fed by gravity from a cistern in the loft, which means the stopcock does almost nothing for them in the short term.
Either way, the fastest way to empty a cylinder is to run the lowest hot tap in the building — usually a ground floor kitchen or cloakroom tap — with the immersion and the boiler off. Never leave an immersion heater switched on with a cylinder that is emptying.
Electrics, properly
Water tracking along a ceiling void reaches light fittings before it reaches the floor. If it is coming through a downlight, out of a ceiling rose, or anywhere near a socket or the consumer unit, treat the circuit as live and dangerous. Do not switch things on to test them. Anything that got wet — fixed wiring, a boiler, a shower unit — needs checking by a registered electrician before it is used again. If water is coming through a ceiling right now, the first ten minutes matter more than the diagnosis.