Vaillant F28: An Ignition Fault, Not a Leak

F28 means the boiler tried to light and no flame signal was detected during the ignition phase, which is a gas supply, ignition or condensate problem. It is not a water leak and it is not our work: this one goes to a Gas Safe registered engineer.

Leak Fix LondonLast updated

A Leak Fix London engineer working on pipework in a London home

We find leaks, and F28 is not one

You will find plenty of leak detection firms happy to take a booking for any boiler fault code. We would rather tell you now: F28 is almost never a leak, and a leak detection visit will not clear it. What follows is what the code means and who to call, because sending you to the right trade first time is worth more to us than a wasted callout.

Vaillant defines F28 as "The flame signal was not detected during the ignition phase". Their engineer documentation puts it as "Start-up failure: Ignit. unsuccessful", with the cause recorded as failure during start-up or ignition unsuccessful, or the gas pressure monitor or thermal cut-out having been triggered. In plain terms: the boiler asked for gas, opened the valve, sparked, and the flame sensor saw nothing. After a set number of attempts it locks out rather than keep releasing gas.

The three causes worth checking before you call anyone

1. A frozen condensate pipe, in cold weather

This is the one you can often fix yourself, and it is the most common cause in a British winter. A condensing boiler produces acidic condensate that drains through a plastic pipe, usually to an outside drain. When that pipe freezes, the condensate backs up, the boiler detects the blockage and refuses to fire.

Vaillant's own guidance: the pipe is usually frozen at its most exposed external point, typically the last stretch just above the drain. Pour warm water along the affected section until the ice clears, and explicitly do not use boiling water from a kettle, which can crack the pipe. Reset the boiler afterwards, and lag the external run with pipe insulation so it does not happen again next cold snap.

How to know this is your cause: the fault appeared during a cold spell, particularly overnight or first thing in the morning, and there may be a gurgling from the boiler as it tries to fire.

2. No gas reaching the boiler

Check, in this order: is the gas stopcock fully open; is the hob lighting; if you are on a prepayment meter, is there credit; has there been a supply interruption in your street. A boiler with no gas will spark, see no flame and throw F28 exactly as if something were broken. Vaillant's advice is the same — if the gas is on and working, it is time to call a professional.

3. Everything else, which is inside the boiler

Vaillant's fault table sends the engineer to check the gas stopcock, gas flow pressure, the gas valve assembly, the air intake pipe for blockage or a loosened screw, the condensate route for blockage, the multiple plug and cable harness, the ignition transformer, cable, plug and electrode, the monitoring electrode, the electronics, the earthing and the CO₂ setting. Electrodes coke up, ignition leads perish, and gas valves drift out of adjustment. All of it is behind the case.

Why you must not open the case

Under the Gas Safety (Installation and Use) Regulations 1998, work on domestic gas appliances must be carried out by a Gas Safe registered engineer, and HSE guidance adds that you should check the back of the engineer's registration card to confirm they are competent on that specific type of appliance. That is the law, not a manufacturer preference, and it is why an F28 that survives the condensate and gas-supply checks is a Gas Safe job and nothing else.

Practically: reset the boiler no more than two or three times. Each reset cycle opens the gas valve and attempts ignition. If it will not light, stop, and get someone qualified to look at it.

The one place F28 and water genuinely overlap

There is a narrow crossover, and it is worth knowing because it is the only reason this page sits in a leak hub.

  • Water inside the boiler case. A leak from the heat exchanger, the hydraulic block or a corroded joint can drip onto the ignition components and the PCB. The result can be an ignition fault that looks electrical and is actually water damage. You would normally see staining under the boiler or on the wall behind it. A Gas Safe engineer diagnoses this, and it is repaired or the boiler is replaced.
  • F28 alongside a pressure gauge that keeps dropping. These are two separate problems. The ignition fault is one job; the pressure loss is a different one, and the pressure loss is the one that may be soaking a floor. See the boiler pressure hub for that half.
  • A blocked condensate route is not a leak either. It is water in the wrong place, but it is the boiler's own waste water, and the fix is clearing or re-routing the pipe.

So who do you call?

SymptomWho
F28 in freezing weather, gurgling from the boilerThaw the condensate pipe yourself with warm water, then reset.
F28 and the hob will not light eitherYour gas supplier. It is a supply problem.
F28 with gas on and no iceGas Safe registered engineer, or Vaillant if in warranty.
F28 plus staining or damp under the boilerGas Safe engineer first. If a pipe outside the boiler is the source, that part is ours.
F28 plus pressure that keeps fallingTwo jobs. Gas Safe for the ignition, and a leak trace for the pressure.

What we would do, if you called us anyway

We would ask three questions on the phone: does the hob light, is the outside condensate pipe frozen, and is the pressure gauge holding. If the answers are yes, no and yes, we would tell you to book a Gas Safe engineer and we would not attend. If the pressure is not holding, that is a real leak question and a separate job, traced with pressure testing, thermal imaging and tracer gas at £150 per hour, with nothing to pay for the search time if we do not find it.

Telling you not to book us is the point of this page.

Frequently asked

Is a Vaillant F28 caused by a water leak?
Almost never. F28 means no flame signal was detected during ignition, which is a gas supply, ignition component or condensate problem. The only water connection is a leak inside the boiler case dripping onto the ignition electronics, which a Gas Safe engineer diagnoses.
Can I fix an F28 myself?
You can thaw a frozen external condensate pipe with warm water, never boiling, and reset the boiler afterwards. You can also check the gas stopcock, your hob and your meter credit. Anything beyond that is inside the appliance and legally requires a Gas Safe registered engineer.
How many times can I reset an F28?
Two or three at most. Each reset opens the gas valve and attempts ignition. A boiler that will not light after a few attempts has a fault that resetting does not address.
Why does F28 keep coming back every winter?
That pattern points strongly at the condensate pipe freezing. Insulating the external run with pipe lagging, and where possible shortening or re-routing it, is the permanent fix. Vaillant recommends lagging as prevention.
My boiler shows F28 and the pressure is also dropping. Which do I deal with first?
Treat them as two faults. The ignition lockout goes to a Gas Safe engineer. The falling pressure means water is leaving a sealed system, and that is the one that damages the building while you wait, so get it traced in parallel.